Examples of typical installations
| Capacity - rack per hour/plates per hour standart speed speed to meet DIN 10510 |
320 / 5760 80 |
| Length between tables (mm) without dryer with dryer |
1350 2200 |
| Wash zone pump rating input/output (kW) water circulation (l/min.) tank capacity (l) tank heating (kW) |
1,5 1200 100 12 |
| Rinser zone (Dual Rinse) water consumption (l/rack) water consumption max. (l/h) tripple Rinse |
x 2,2 260 o |
| Booster (kW) with cold water / 50 ° hot water with C30 energy recovery with CHP 18 heat pump |
24 / 12 15 12 |
| Drying zone heating (kW) air circulation (m³/h) motor (kW) |
3 / 4,5 2200 0,5 |
| Standart equipment / options 2 speed heat recovery condensor heat pump energy recovery, PROCLIM PROCLEAR rinse optimiser integral rinse pump insulation push button drain down single point vent connection autotimer 6+4 wash system mains switch |
x 120 / 80 o o x x x x x x x x |